Facebook
Back to Products Ask for price and availability

RWT MV/LV transformer station switchgears for indoor installation

Application

  • For indoor installation and container MV/LV transformer stations.;
  • For industrial and construction sites;
  • Providing power supply, distribution and metering of electricity as well as protection of electrical devices against consequences of shortings and overloads on the low voltage side.

Accessories

Enclosure

  • Compact, lightweight modular design ensuring the required rigidity of the structure; made of steel galvanised or aluminium profiles connected with cast aluminium or polyamide connectors which enable connection of individual elements without any tools;
  • High mechanical strength and protection level that prevents penetration of dust and mechanical damages;
  • Full enclosure, covers made of steel sheet with an anti-corrosion coat, powder painted in any colour, provided as fixed or tilting units for easy inspections and thermography observation;
  • The internal space with isolated parts: functional modules, current circuits;
  • Allows to change the power supply side by replacement of the switchgear power supply module or installation of the metering module;
  • Connection of the modules with screws (without riveting or welding) for quick removal of the modules, delivery of the switchgear in modules to the place of installation (when space is limited) and assembly on site;
  • Set on an additional frame adjusted to the dimensions of the cable channel;
  • The switchgear can be built to any dimensions, to meet the specific needs of the Client;
  • Angular connection of modules, e.g. at 90°;
  • Eyebolts for (travelling) crane transport;
  • The marking of the switchgear with permanent engraved plastic plates to enable identification of all key elements.

Current circuits

  • The current circuits of the incoming and outgoing modules made of screwed copper flat bars with the cross section adjusted to current load, fitted with pressed rivet nuts to enable installation of rail components when energised;
  • The connection strip for the terminal of portable earthing devices.

Configuration

MZ: the incoming module

  • The power supply for the module is provided with busbars or cables with brass terminals ZLM-2×300 to the current circuit strips;
  • The incoming busbar bridge fully covered;
  • The insulator switch (fuse) or power switch up to 2500 A;
  • The earthing clamps for connection of earthing devices;
  • The module may be optionally fitted with PK/EQ.

MO: the outgoing module

  • Disconnecting switches or fuse bases (strip-mounted or moulded-case types);
  • The module is optionally fitted with additional elements, e.g. generator terminals;
  • Covered redundancy circuits;
  • Cable clamps.

MP: the metering and balancing module compliant with the guidelines of the energy distributor and seller;

SON: the lighting module, the control circuit for street lighting of the traffic route in the vicinity of the station;

OPW: auxiliaries circuits, station lighting (16A/D01), 230 V socket (16A/A01);

PK/EQ: monitoring, analysis of quality of electricity, metering voltage transformers, grid parameters meter (analogue or digital), analyser of electricity quality parameters, communication;

BK: a capacitor to compensate idle running of the transformer / a battery of capacitors.

Basic technical data

  • Rated operational voltage230/400 V
  • Insulation rated voltage500/690 V
  • Rated frequency50 Hz
  • Impulse withstand voltage8 kV
  • Busbar rated continuous current1250/1600/2500 A
  • Outgoing busbar rated continuous current160/250/400/630 A
  • Rated short-time withstand current40 kA (1 s.)
  • Rated peak withstand current80 kA
  • Internal arc short-circuit current20 kA
  • IP protection level4X/2X
  • IK level of protection against mechanical impact10
  • Appliance classI
  • Dimensions of incoming / outgoing terminals2 x 4 x 240 mm² / 4 x 240 mm²
  • Network arrangementsTN-S, TN-C, TN-C-S, TT, IT
  • Height / width / depthwithout limitations

Compliance with standards

  • PN-EN 61439-1 – „Low-voltage switchgear and controlgear assemblies. Part 1: General rules”;
  • PN-EN 61439-2 – „Low-voltage switchgear and controlgear assemblies – Part 2: Power switchgear and controlgear assemblies”;
  • PN-E-05163 – „Enclosed low-voltage switchgear and controlgear assemblies. Guide for testing under conditions of arcing due to internal fault”;
  • PN-EN 50274– „Low-voltage switchgear and controlgear assemblies – Protection against electric shock – Protection against unintentional direct contact with hazardous live parts”;
  • PN-EN 62208 – „Empty enclosures for low-voltage switchgear and controlgear assemblies – General requirements”;
  • PN-EN 60529 – „Degrees of protection provided by enclosures (IP Code)”;
  • PN-EN ISO 4628 – „FPaints and varnishes – Evaluation of degradation of coatings – Designation of quantity and size of defects, and of intensity of uniform changes in appearance – Part 6: Assessment of degree of chalking by tape method”;
  • PN-EN ISO 2409 –„Paints and varnishes – Cross-cut test”;
  • PN-EN 62262 – „Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code). (IDT PN-EN 50102:2001)”.

Downloads